一种基于对称结构测试罩耦合标准流导的抽速测量装置设计
基金项目(Foundation):
邮箱(Email): tianl88108089@163.com;gsluyw@163.com;
DOI: 10.13922/j.cnki.cjvst.202603018
发布时间: 2026-09-16
出版时间: 2026-09-16
网络发布时间: 2026-09-16
移动端阅读
摘要:

传统高/超高真空泵采用流量法结合流导法,实现测试罩内处于(10-1~10-6)Pa压力下的抽速测试,存在测试罩入口压力范围窄、测试结果不确定度大等局限。本文提出了一种基于对称结构测试罩耦合标准流导的高/超高真空泵抽速测试新方法,采用对称结构设计,用两组相同测试罩分别安装被测真空泵和标准流导,以真空计作为比较器分别测量同一气体流量在两个测试罩内形成的气体压力,将标准流导元件对某种气体的分子流导值作为参考标准计算得到被测泵对该气体的抽速。该方法避免了传统方法使用真空计测量绝对压力偏差较大、仅能测量等效气体抽速等问题,也无需提供已知的标准气体流量,可实现测试罩内气体压力在(10-1~10-7)Pa范围内的抽速测试,测量结果的合成标准不确定度减小到2.5%。

Abstract:

The pumping speed of high vacuum/ultra-high vacuum(HV/UHV) pumps is commonly tested by combining the flow-rate method with the conductance method under the pressure range of 10-1 to 10-6 Pa. Nevertheless,this technique is constrained by drawbacks including the narrow inlet-pressure range of the test dome and large measurement uncertainty of test results. This paper proposes a novel pumping-speed measurement approach for HV/UHV pumps, which employs a symmetrically structured test dome coupled with a standard conductance element. In this symmetric configuration, two identical test domes are fitted, respectively, with the pump-under-test and the standard conductance element. Vacuum gauges are utilized as comparators to measure gas pressures induced by the identical gas flow rate in the two test domes. The pumping speed of the pump under test for a given gas is calculated by taking the molecular conductance of the standard conductance element for that specific gas as the reference standard. The proposed method overcomes the limitations of conventional techniques, such as the considerable deviations in the absolute-pressure readings of vacuum gauges and the restriction to equivalent-gas pumping-speed measurement. Furthermore, it eliminates the requirement for a known standard gas flow rate and enables pumping-speed measurement over the pressure interval of 10-1 to 10-7 Pa in the test dome. The combined standard uncertainty of the measured results is reduced to 2.5%.

参考文献

[1]Wang X D, Ba D C, Yang N H, et al. The theory of structure design for new type of compound molecular pump[J].Vacuum,1993(3):26-31 (王晓冬,巴德纯,杨乃恒,等.新型复合分子泵结构设计理论的研究[J].真空,1993(3):26-31(in Chinese))

[2]Ba D C, Wang X D, Liu K, et al. Progress in R&D of modern turbo-molecular pumps[J]. Vacuum,2010,47(4):1-6 (巴德纯,王晓冬,刘坤,等.现代涡轮分子泵的进展[J].真空,2010,47(4):1-6(in Chinese))

[3]Chen Q R, Wei M M, Lu Y W, et al. Pumping characteristics of N2 by non-evaporable getter pumps[J]. Chinese Journal of Vacuum Science and Technology,2023,43(2):79-83 (陈千睿,魏萌萌,卢耀文,等.非蒸散型吸气剂泵(NEG)对N2气的抽气特性研究[J].真空科学与技术学报,2023,43(2):79-83(in Chinese))

[4]Wang Y Z, Chen X. Vacuum technology[M]. Beijing:Beihang University Press, 2007 (王欲知,陈旭.真空技术[M].北京:北京航空航天大学出版社, 2007(in Chinese))

[5]Da D A. Vacuum design handbook[M]. Beijing:National Defense Industry Press, 2004 (达道安.真空设计手册[M].北京:国防工业出版社, 2004(in Chinese))

[6]General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China,Standardization Administration of China. GB/T 7774-2007 Vacuum technology-Turbomolecular pumps-Measurement of performance characteristics[S]. Beijing:Standards Press of China, 2008 (中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会. GB/T7774-2007真空技术涡轮分子泵性能参数的测量[S].北京:中国标准出版社, 2008(in Chinese))

[7]International Organization for Standardization. ISO 21360-4:2018 Vacuum technology—Standard methods for measuring vacuum-pump performance—Part 4:Turbomolecular vacuum pumps[S]. Geneva:International Organization for Standardization, 2018

[8]Ministry of Industry and Information Technology of the People’s Republic of China. JB/T 11081-2011 Vacuum technology—Refrigerator cooled cryopumps[S]. Beijing:China Machine Press, 2011 (中华人民共和国工业和信息化部. JB/T 11081-2011真空技术制冷机低温泵[S].北京:机械工业出版社, 2011(in Chinese))

[9]General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China,Standardization Administration of China. GB/T 25755-2010 Vacuum technology-Sputter-ion pumps-Measurement of performance characteristics[S]. Beijing:Standards Press of China, 2011 (中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会. GB/T25755-2010真空技术溅射离子泵性能参数的测量[S].北京:中国标准出版社, 2011(in Chinese))

[10]Gaede W. Die molekularluftpumpe[J]. Annalen der Physik,1913,346(7):337-380

[11]Danielson P. How to match pumping speed to gas load[J].Research&Development,2000,42(12):30-31

[12]Malyshev O B. Characterisation of a turbo-molecular pumps by a minimum of parameters[J]. Vacuum, 2007,81(6):752-758

[13]Guo N, Qiu J W, Jiang H C. Xe pumping speed testing for molecular pump[J]. Vacuum,2007,44(2):15-17 (郭宁,邱家稳,江豪成.分子泵对Xe气抽速的测试[J].真空,2007,44(2):15-17(in Chinese))

[14]Li D T, Cheng Y J. Applications of non-evaporable getter pump in vacuum metrology[J]. Chinese Journal of Vacuum Science and Technology,2011,31(2):234-236 (李得天,成永军.非蒸散型吸气剂泵在真空计量中的应用研究[J].真空科学与技术学报,2011,31(2):234-236(in Chinese))

[15]Geng J, Wang X D, Guo M R, et al. Research on measuring method of pumping speed for miniature sputter ion pump[J]. Measurement,2022,190:110736

[16]Jitschin W, Bernhardt K H, Lachenmann R, et al. Measuring the pumping speed of rough vacuum pumps:conventional stationary method vs intermittent pump-down method(new standard DIN 28432)[J]. Vacuum, 1996,47(6-8):505-509

[17]Zhang H Z, Ge J G, Yao P, et al. Development and performance study of 10-9~10-1 Pa wide-range ionization gauge[J]. Vacuum and Cryogenics,2022,28(4):392-396(张虎忠,葛金国,姚鹏,等. 10-9~10-1 Pa宽量程电离真空计研制与性能研究[J].真空与低温,2022,28(4):392-396(in Chinese))

[18]Lu Y W, Dong Y N, Yan R, et al. Lab-built testplatform for pumping-speed measurement and calibration of CF400 molecular pump[J]. Chinese Journal of Vacuum Science and Technology,2020,40(5):416-420 (卢耀文,董云宁,闫睿,等.一种基于CF400接口分子泵抽速测试装置[J].真空科学与技术学报,2020,40(5):416-420(in Chinese))

[19]Lu Y W, Chen X, Li D T, et al. Novel type of portable vacuum gauge calibration apparatus[J]. Chinese Journal of Vacuum Science and Technology, 2013, 33(5):462-467 (卢耀文,陈旭,李得天,等.便携式真空计校准装置[J].真空科学与技术学报,2013,33(5):462-467(in Chinese))

[20]Lu Y W, Bai X C, Dai J S, et al. Self-developed portable calibration apparatus of vacuum gauge with 105 Pa~10-7Pa range:an instrumentation study[J]. Chinese Journal of Vacuum Science and Technology,2020,40(6):531-535(卢耀文,柏向春,代建设,等.一种105~10-7 Pa现场真空计校准装置的设计[J].真空科学与技术学报,2020,40(6):531-535(in Chinese))

[21]Feng Y, Zhang D X, Li D T, et al. Study on measurement method of small orifice conductance using gas microflowmeter[J]. Vacuum and Cryogenics, 2009, 15(2):95-98,107 (冯焱,张涤新,李得天,等.气体微流量计测量小孔流导方法研究[J].真空与低温,2009,15(2):95-98,107(in Chinese))

[22]Szwemin P J, Niewinski M, Szymanski K. Conductance of orifices in the spherical and cylindrical chambers of calibration systems[J]. Vacuum,1995,46(8-10):875-878

[23]Zhang Q, Li D T, Yang C Q, et al. Research on measurement method for orifice conductance[J]. Vacuum and Cryogenics,2017,23(2):76-81 (张琦,李得天,杨长青,等.限流元件流导测量技术研究进展[J].真空与低温,2017,23(2):76-81(in Chinese))

[24]Lu Y W, Wu D, Chen C, et al. Novel standard gas flowmeter covering(10-1~10-10)Pa·m3/s range:an instrumentation study[J]. Chinese Journal of Vacuum Science and Technology, 2020, 40(7):674-678(卢耀文,吴端,陈春,等.一种(10-1~10-10)Pa·m3/s标准气体流量计的设计[J].真空科学与技术学报, 2020, 40(7):674-678)

[25]Li H T. Research on test method of minimal pumping speed of micro sputtering ion pump[D]. Shenyang:Northeastern University, 2020 (李海涛.微型溅射离子泵极小抽速的测试方法研究[D].沈阳:东北大学, 2020(in Chinese))

[26]Yao X Q, Dong Y N, Yan R, et al. Performance study on portable calibration apparatus of mass spectrometers for partial pressure[J]. Chinese Journal of Vacuum Science and Technology,2024,44(4):306-311 (姚雪琦,董云宁,闫睿,等.便携式分压力质谱计校准装置的性能测试研究[J].真空科学与技术学报,2024,44(4):306-311(in Chinese))

[27]Ni Y C. Practical evaluation of measurement uncertainty(2nd edition)[M]. Beijing:China Metrology Publishing House, 2007 (倪育才.实用测量不确定度评定(第二版)[M].北京:中国计量出版社, 2007(in Chinese))

[28]Qiao J Y, Ma K Y, Song L B, et al. Uncertainty evaluation of vacuum pump test system[J]. Coal Mine Machinery,2017,38(10):76-79 (乔金宇,马琨岩,宋龙波,等.真空泵测试系统不确定度评定[J].煤矿机械,2017,38(10):76-79(in Chinese))

[29]Ni Y C. Practical evaluation of measurement uncertainty(3rd edition)[M]. Beijing:China Metrology Publishing House, 2009 (倪育才.实用测量不确定度评定(第三版)[M].北京:中国计量出版社, 2009(in Chinese))

基本信息:

DOI:10.13922/j.cnki.cjvst.202603018

中图分类号:TB752

引用信息:

[1]董云宁,田露,卢耀文,等.一种基于对称结构测试罩耦合标准流导的抽速测量装置设计[J].真空科学与技术学报,2026,46(10):915-920.DOI:10.13922/j.cnki.cjvst.202603018.

发布时间:

2026-09-16

出版时间:

2026-09-16

网络发布时间:

2026-09-16

检 索 高级检索

引用

GB/T 7714-2015 格式引文
MLA格式引文
APA格式引文